Description
Application: The 1690 Series narrow stile touch bar exit devices provide safe and reliable egress that is ideal for aluminum doors.
• The 1690 Series design is ideal for demanding, moderate-traffic applications. The vertical rods and latch mechanisms are concealed in the vertical door stile, ensuring ideal operation. Cast metal cover plates and end caps hold up to rigorous use. A quick, single-point dogging feature in the housing deactivates the device, permitting unrestricted traffic flow. The 1690 Series may also be used to retrofit a 1990 Series crossbar device.
Specifications:
• Hand: Field reversible, non-handed.
• Strikes: PB-48 top.
• Fasteners: All machine screw mounting. Device mounting fasteners are concealed, latch fasteners are exposed to egress side.
• End caps: Black powder-coated metal end caps. PB-314
• Vertical rods: 7′ standard, extension rods available up to 10′. Rod extension kits available.
• Dogging feature: Hex key dogging standard PB-232, PBX-16, except EL where must use hold back feature on outside cylinder.
• Cylinder: Rim, night latch (NL) or hold back (HB) feature available. Field selectable.
• Doors: 1 3⁄4″ thick metal doors, specify if other.*
• Projections: 3 3⁄8″ in neutral position, 2 3⁄8″ in dogged position. Pushbar height is 2 1⁄2″.
• Stile: 1 3⁄4″ minimum.
Latches:
• Standard top – SU latch. PB-130
• Standard bottom – hex bottom bolt.
• Optional top – ES – electric strike top latch, device must be less bottom rod (LBR).
• Optional bottom – RL – rod bottom latch. – PL – pullman bottom latch.
Finishes: US28, DC13, DC 35, US3, US10, US26, US26D. Centercase and end cap are powder-coated black only.
Functions:
| Model | Trim package | Type | Function |
| 1690 | No outside trim | 6 | 01 |
| 1691 | Pull only (9970) | 6 | 02 |
| 1692 | Cylinder only | 6 | 03/04 |
| 1694 | Pull and cylinder | 6 | 02/03/04 |
* 9970 is for use on HM and Alum doors only. Not for use on wood doors.
Sizes: 30″, 36″, 42″, and 48″.
| Length | Minimum door size (non-EL) |
Minimum door size (EL) |
| 30″ | 24″ | 28 1⁄2″ |
| 36″ | 30″ | 34 1⁄2″ |
| 42″ | 36″ | 40 1⁄2″ |
| 48″ | 42″ | 46 1⁄2″ |
Electric functions:
• EL – electric latch retraction,
• ED – electric dogging (both EL and ED require PS914-2RS minimum power supply).
• RX – request to exit switch, monitors pushpad SPTD switch.
Certifications:
• ANSI: Certified ANSI A156.3 grade 1 standards.
• Hurricane: 1690 devices are used for hurricane rated door openings. Consult door manufacturer’s listing.






Reviews